| Oscilloscope | ||
|---|---|---|
| Versioni | PicoScope 6402 | PicoScope 6403 |
| Bandwidth |
350 MHz (-3 dB) with TA101 probes or on 50 Ω setting; switchable 20 MHz bandwidth limiters |
|
| Channels | 4 | |
| Vertical resolution | 8 bits | |
| Enhanced vertical resolution | 12 bits | |
| Accuracy | ±3% | |
| Rise time | 1.0 ns (10% to 90%) | |
| Sensitivity | 10 mV/div to 4 V/div at x1 zoom | |
| Input ranges (full scale) | ±50 mV to ±20 V in 9 ranges (up to ±5 V when 50 Ω input selected) | |
| Input characteristics | 1 MΩ in parallel with 15 pF (AC or DC) or 50 Ω (DC only) | |
| Input type | Single-ended, BNC connector | |
| Input coupling | Software selectable AC/DC | |
| Overload protection | ±100 V to ground (1 MΩ inputs), 5.5 V RMS (50 Ω inputs) | |
|
Maximum
sampling
rate
(single
shot) 1 channel in use 2 channels in use 3 or 4 channels in use |
5 GS/s 2.5 GS/s 1.25 GS/s |
|
|
Maximum
sampling
rate (continuous streaming mode) |
13 MS/s (Record length limited to 1 GS in PicoScope, unlimited when using the supplied API) | |
|
Buffer
memory (shared between active channels) |
32 MS |
1 GS |
| Waveform buffer | Up to 10000 waveforms | |
| Timebase ranges | 1 ns/div to 200 s/div | |
| Timebase accuracy | 5 ppm | |
| Triggers | ||
|---|---|---|
| Source | Any input channel or AUX input | |
| Basic triggers | Auto, rapid, repeat, single, none | |
| Advanced triggers | Rising edge, falling edge, edge with hysteresis, logic level, pulse width, runt pulse, dropout, window, delayed | |
| Trigger level | Adjustable over whole of selected voltage range | |
| Re-arm time | Less than 1 µs on fastest timebase | |
| Maximum pre trigger delay | 100% of capture size | |
| Maximum post trigger delay | 4 billion samples | |
| Arbitrary Waveform Generator | ||
|---|---|---|
| Arbitrary waveform buffer | 16384 samples | |
| Standard waveforms | Sine, square, triangle, ramp (up/down), sin (x)/x, Gaussian, half-sine, white noise, DC level | |
| Bandwidth | DC to 20 MHz | |
| Sample rate | 200 MS/s | |
| Output characteristics | BNC, 50 Ω | |
| Resolution | 12 bits | |
| DC accuracy | 1% | |
| Amplitude range | ±250 mV to ±2 V (±2.5 V with DC offset) | |
| DC offset | ±1 V (max. combined output ±2.5 V) | |
| Auxiliary Input (AUX) | ||
|---|---|---|
| Input impedance | 50 Ω | |
| Input coupling | DC | |
| Maximum input voltage | ±5 V | |
| Input threshold | ±1 V | |
| Probe Calibration Output | ||
|---|---|---|
|
Signal output type |
1 kHz square wave, 2 V pk-pk, 600 Ω | |
| Spectrum Analyser | ||
|---|---|---|
| Bandwidth | 350 MHz | |
| Frequency range | DC to 350 MHz | |
| Maximum number of bins | 1,048,576 | |
| Display modes | Magnitude, peak hold, average | |
| Window types | Rectangular, Gaussian, triangular, Blackman, Blackman-Harris, Hamming, Hann, flat-top | |
| PC Requirements | ||
|---|---|---|
| Minimum |
Processor:
Pentium
II
processor,
or
equivalent Memory: 64 MiB (XP) / 512 MiB (Vista) / 1 GiB (Win 7) minimum Operating system: 32 or 64-bit edition of Microsoft Windows XP SP2, Vista or Windows 7 Ports: USB 2.0 compliant port |
|
| Recommended |
Processor:
2
GHz
Pentium
IV
processor,
or
equivalent Memory: 256 MiB (XP) / 1 GiB (Vista / Win 7) Operating system: 32 or 64-bit edition of Microsoft Windows XP SP2 (or above), Vista or Windows 7 Ports: USB 2.0 compliant port |
|
| Environmental | |||
|---|---|---|---|
|
Operating
environment Temperature range |
0 °C to 40 °C (20 °C to 30 °C for quoted accuracy) |
||
|
Storage
environment Temperature range Humidity |
-20 to +60 °C 5 to 95% RH, non-condensing |
||
| Physical Dimensions | ||
|---|---|---|
| Dimensions | 255 x 170 x 40 mm (approx 10 x 6.7 x 1.6 in) | |
| Weight | <1 kg (approx 2.2 lb) | |
| Software | ||
|---|---|---|
|
PicoScope 6 for Windows |
PicoScope
6 is
your
complete
test
and
measurement
lab
in
one
application.
Features
include: Capture modes - oscilloscope, spectrum and persistence modes Channel maths - calculate the sum, dfference, product, inverse or create your own custom function using standard arithmetic, exponential and trigonometric functions Automated measurements Scope mode: AC RMS, cycle time, DC average, duty cycle, falling rate, fall time, frequency, high pulse width, low pulse width, maximum, minimum, peak-to-peak, rise time and rising rate Spectrum mode: frequency at peak, amplitude at peak, total power, total harmonic distortion (THD), total harmonic distortion plus noise (THD+N), spurious-free dynamic range (SFDR), signal+noise+distortion to signal+noise ratio (SINAD), signal to noise ratio (SNR) and intermodulation distortion (IMD) Export data formats - Comma separated values (CSV), tab delimited (TXT), windows bitmap (BMP), graphics interchange format (GIF), portable network graphics (PNG), MATLAB 4 format (MAT) Full details on PicoScope 6 |
|
|
Software development kit |
A growing collection of drivers and example code for various programming languages | |
| Language support | ||
|---|---|---|
|
Software PicoScope 6 |
Full support for English, French, Italian, German and Spanish. Menus and dialogs only for Dutch, Hungarian and Simplified Chinese. |
|
|
Documentation User’s guide Programmer’s guide Quick Start Guide |
English, French, German, Italian, Spanish English English, French, German, Italian, Spanish |
|
| General | |
|---|---|
| Additional hardware (supplied) | USB 2.0 cable, carry case, user manuals and software CD-ROM |
| PC interface | USB 2.0 (USB 1.1 compatible) - cable supplied |
|
Power
supply AC adaptor |
12 V
±2 V
@
3.5
A External adaptor supplied (suitable for USA, UK, Europe and Australasia) |
| Compliance |
European
EMC
and
LVD
standards FCC Rules Part 15 Class A RoHS compliant |
| Warranty | 5 years |