HOME  |  AZIENDA  |  PRODOTTI  |  SERVIZI  |  SUPPORTO  |  LISTINO  |  NEWS  |  CONTATTI  |  LINKS
 

MOBILE COMMUNICATIONS DC SOURCE
Dual Channel DC Source and Current Sink Capability

  Mobile Communications DC source Characteristics  
  • Standard GPIB Interface
  • Electronic Calibration via Front Panel or GPIB
  • Programmable Overvoltage and Overcurrent Protection
  • Low Ripple and Noise Output
  • Output Enable / Disable
  • Remote Sensing Function
  • Programmable Up/Down Fine Tuning
  • Power-Off Memory

 
  Specifications  
 
AC Input One internal switch permits operation of 115 or 230(240) Vac line Voltage
Input Current
115 VAC / 230VAC
1.35A /0.7A 2.7A / 1.35A
Fuse Rating
115VAC / 230VAC
AC input is protected by a rear panel mounted fuse
2.5A /1.25A
4A / 2A
Power 115 Vac or 230 Vac ± 10%; 50 to 60Hz
Maximum VA / Power 160VA /125W 315VA/240W
Peak Inrush Current 20A 30A
DC Output Programming Range
Voltage/Current
0~8V/0~3A 0~18V(20V)/ 0~4A
Sink Current 0 to -3A 0 to -4A
DC Output Programming Range
Voltage/Current

0 to 8V /-3A TO 3A
High Range  - 3A to 3A
Low Range   - 3mA to 3mA
0 to 18V(20V)/
-4A to 4A
programming Resolution (LSB)
Voltage/Current
2mA / 1mA 10mV / 2mA
programming Accuracy
Voltage/Current
0.05% + 2LSB / 0.15% + 5LSB
Sink Current Tracking 0.3% + 10 LSB
Load Effect 
Voltage/Current
0.001% + 1mV / 1mA
Remote sense operation is possible with up to 0.5V drop for positive and negative output load leads.
Source Effect
Voltage/Current
1mV / 1mV
PARD (Periodic and Random Deviation and Noise)
RMS/PK-PK(20Hz-20MHz) with output ungrounded
Voltage/Current
0.5mVrms / 10m Vp-p / 1mArms 1mVrms/10mVp-p/1mArms
Temperature Coefficient
Voltage/Current
100ppm/ºC / 200ppm/ºC
Drift (Stability)
Voltage/Current
0.01% + 1mV / 0.1% + 5mA
Load Transient Response
Recover Time
< 50us
Programming UP/DOWN Speed
Tup/Tdn
LSB

1ms/2ms
5ms/10ms
READBACK Resolution
Voltage/Current

2mV/1mA
High Range 1mA
Low Range -1£gA
10mV/2mV
READBACK Accuracy
Voltage/Current
0.1% + 2LSB / 0.2% + 5LSB
READBACK Temperature Coefficient
Voltage/Current
100ppm + 4mV /200ppm + 4mA
Output Isolation 240Vdc
Neither output terminal may be more than 240Vdc fromchassis ground.
Temperature Rating/Humidity Range Operating 0ºC to 40ºC/30 to 80% RH Storage  -20ºC to 70ºC / 20 to 80% RH
GPIB Interface Capability SH, AH1, T6, TE0, L4, LE0, SR0, PP0, DC1, DT0, C0, E1
Weight 7.30 kgs ( 16lbs ) 9kgs ( 20lbs )
Dimensions 8.4" X 5.2" X 15.7" for all models

- HOMEPAGE MOTECH - SPECIFICHE - DOWNLOAD -